Here you see our references regarding: Gas Analysis



Project details: Quantum cascade laser spectroscopy for N2O trace gas analysis

 

 

 

Industries

  • Gas Analysis, Medical Technology

 

Technology fields

  • Bus Systems and Radio, CAE, Software Development, Gas Analysis, Optical Measuring Systems; Measurement, Control and Regulation Technology

 

Project requirements

  • The aim of the project was the development of a compact, well-integrable analyzer module consisting of a long way cell (Herriott) and an electronic control for trace gas analysis of N2O. Beside N2O, the gases CO, CO2 and O3 shall be determinable. A fast response time (T90: 1-2 seconds), no cross-sensitivities to other gases, and a low detection limit of <10 ppbV are the characteristic conditions that were set on this project.

 

Facts / Highlights

  • No LN2 necessary, detector is cooling with ambient air
  • Simple calibration, even without N2O-span gases, possible
  • Completely fulfills EURO VI requirements
  • Compatible through compact construction
  • High selectivity and sensitivity
  • No cross-sensitivities
  • Adjustment for various gases is possible
  • Electronics with a variety of lasers operable (QCL, DFB, ICL, ...)

 

Services of KNESTEL

  • Potential analysis, target price estimate, project management; development of software, hardware and optics; support with the mechanical construction, EMC testing, serial production

 

Possible applications

  • Gas analysis in research, development and quality assurance
  • Environmental technology
  • Process monitoring
  • Medical technology, breath gas analysis

 

 » as PDF-Download

 

Project details: PAS sensor module for trace gas analysis

 

 

 

Industries

  • Gas Analysis

 

Technology fields

  • Optical Measuring Systems; Measurement, Control and Regulation Technology

 

Project requirements

  • The aim of the project was the development of a photoacoustic sensor for measuring NO2 concentrations in exhaust gases with a detection limit of <50 ppb using the photoacoustic principle. A special challenge was to make the measurement independent of ambient or flow noises. Another project goal was the operation of the cell in acoustic resonance, for what new methods had to be developed to stabilize (resonance tracking). This enables continuous measurement during the gas flow, regardless of changes in the temperature or the gas concentration.

 

Facts / Highlights

  • Response time: <1 second
  • Detection limit NO2: <50 ppb
  • Gas flow rate up to 1000 ml / min
  • Integrated heater
  • Online resonance frequency tracking parallel to the concentration measurement
  • Continuous measurement possible
  • Can be combined with laser spectroscopy, for example LUGGI

 

Services of KNESTEL

  • Target price estimate, project management, specification of requirements, project planning, development of hardware, electrical and mechanical construction, EMC testing, prototyping, serial production

 

Possible applications

  • Trace gas analysis in the automotive industry, environmental technology, monitoring maturity level or Medical Technology
  • Measuring principle for all active IR/UV gases applicable by replacing the light source

» as PDF-Download

 

Project details: Chemiluminescence detector (CLD) for NOx measurement

 

 

 

Industries

  • Automotive, Gas Analysis

 

Technology fields

  • Measurement, Control and Regulation Technology; Optical Measuring Systems

 

Project requirements

  • The aim of the project was to develop a device for measuring the concentration of nitrogen oxides (NO and NOx) in the exhaust gas of vehicles and combustion processes. The challenge here was to cover an extremely high dynamic range with measuring ranges between 0 - 1ppm as well as 0 - 5000ppm. The detection limit should be only a few parts per billion (1 - 5ppb). Another challenge is to minimize the distortion of the measurement signal by components in high concentrations, such as water and carbon dioxide. In addition, the unit had to be designed for a limited space.

 

Facts / Highlights

  • T90: <1 second
  • Limit of detection (LOD): 1-5ppb
  • No delay time
  • Measuring range: 0-1ppm / 0-5000ppm

 

Services of KNESTEL

  • Target price estimate, project management, requirements specification, project planning, development of hardware, electrical and mechanical construction, EMC testing, prototyping, serial production

 

Possible applications

  • Exhaust gas analysis in the automotive sector
  • Immission Measurement
  • Emission Measurement

» as PDF-Download

 

Project details: OEM-NDIRflex Non-Dispersive InfraRed sensor

 

 

Industries

  • Trace Gas Analysis, Automotive, Testing and Measuring Technology

 

Technology fields

  • Optical Measuring Systems; Measurement, Control and Regulation Technology

 

Project requirements

  • The aim of the project was the development of a NDIRflex measuring bench with modular design for different cuvette lengths. The measured values should be accessed via a CAN or rather a serial RS232 communication protocol. Furthermore, it should also be realized a heated cuvette and a Peltier cooling for the thermopile receiver. About a further measuring input, an electrochemical O2 sensor should be evaluated additionally. A further requirement was to determine the flow of the gas to be measured and a pressure or temperature compensation of the measured values.

 

Facts / Highlights

  • Analysis of up to four thermopile channels
  • Modular design for different cuvette lengths
  • Temperature and pressure compensation
  • CAN and RS232 interface
  • Integrated pressure sensors for flow determination
  • Measuring input for electrochemical O2 sensor

 

Services of KNESTEL

  • Target price estimate, project management, requirements specification, project planning, development hardware, electrical and mechanical construction, EMC testing, prototyping, serial production

 

Possible applications

  • Emission and immission measurements of industrial and process gases
  • Determination of pollutants concentrations in the air
  • Quality assurance in manufacturing processes
  • Maturity monitoring of fruit and vegetables
  • Exhaust gas measurements in the automotive industry or in power plant technology

 

» as PDF-Download

From which industry field you like to see our references:




Your contact person:
Dr.-Ing. Markus Knestel

Tel.: +49 (0) 83 72 - 7080
Fax.: +49 (0) 83 72 - 2384
E-Mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

© 2011 Knestel Unternehmensgruppe – Alle Rechte vorbehalten.